electrician people - here's a question for you.
|
Manesero posted:
It was Rye bread.
Well, there's your problem right there! Should have tried a hushpuppy. Possibly cornbread...
-----signature-----
.
Mangler had an accident on the way home from the liquor store. He was run off the road and crashed into a woman's clinic. It was one giant Pabst smear.
-Bou_Te
.
Soylent CLiKK -- It's PEEEEEOPLEEE
|
Tacit_MT
Posts: 29
Registered: 2000-12-12 14:41:56
|
Date Posted:
1/1/00 12:00am
Subject:
electrician people - here's a question for you.
|
You are using a standard single pole light switch (2 terminals + 1 ground) and not a 3 way switch (3 terminals + ground), correct? And you're only connecting the black wires to the switch, one line side (to the breaker) the other the load side (to the lights)?
-----signature-----
follower of Tasher of the Knights of Fortune
Rydia - maxed all tinkers, spec all tinkers, 38% imbue
|
Manesero
Posts: 32
Registered: 2001-12-21 13:39:15
|
Date Posted:
1/1/00 12:00am
Subject:
electrician people - here's a question for you.
|
Tacit_MT posted:
You are using a standard single pole light switch (2 terminals + 1 ground) and not a 3 way switch (3 terminals + ground), correct? And you're only connecting the black wires to the switch, one line side (to the breaker) the other the load side (to the lights)?
Single Pole light switch like this one here.
http://www.homedepot.com/h_d1/N-5yc1v/R-202026988/h_d2/ProductDisplay?langId=-1&storeId=10051&catalogId=10053&superSkuId=202887016
Black wire from the breaker line attaches to several other black wires from other outlets in the same box. So I hooked up a short black wire from the breaker line to the light switch.
White wire from the breaker line attaches to several other white wires from other outlets in the same box. I hooked up a short white wire from the breaker line to the light switch.
Ground wire from the breaker line attaches to several other ground wires from other outlets in the same box. I hooked up a short ground wire from the breaker line to the light switch.
-----signature-----
|
the_tessa
Title: I can touch my toes!
Posts: 473
Registered: 2003-3-24 00:53:06
|
Date Posted:
1/1/00 12:00am
Subject:
electrician people - here's a question for you.
|
sounds like there is something borked with the switch
-----signature-----
Elitist
 01-02-06
___________________________
http://rivergrows.blogspot.com/
|
Tacit_MT
Posts: 29
Registered: 2000-12-12 14:41:56
|
Date Posted:
1/1/00 12:00am
Subject:
electrician people - here's a question for you.
|
Manesero posted:
I hooked up a short white wire from the breaker line to the light switch.
There's your problem. How you got it to work at all is beyond me. Don't hook neutrals (white wires) to your switch. Your switch should 'switch' off the current on your hot (black) wires.
Your ground wire from your breaker (or receptacle, wherever you are tapping into power) should run to your lights and hook to the green terminal on your switch. White wires should run directly from your receptacle to your lights. Black wire from receptacle to one side of switch, black wire from lights to other side of switch.
-----signature-----
follower of Tasher of the Knights of Fortune
Rydia - maxed all tinkers, spec all tinkers, 38% imbue
|
Hyperimiator
Title: Maximus Probus
Posts: 840
Registered: 2001-7-20 18:55:36
|
Date Posted:
1/1/00 12:00am
Subject:
electrician people - here's a question for you.
|
image=http://www.thecircuitdetective.com/tourcircuit.htm
http://knol.google.com/k/single-pole-switch-wiring-methods#
It is all explained above
-----signature-----
The Hyperimiator song
http://www.wfmu.org/listen.ram?show=1639&starttime=1:40:35
"  ou are never going to be able to vote for the revolution. Get that hope out of your mind" -Jerry Rubin
http://www.youtube.com/user/Hyperimiator#p/u
|
|
|
Date Posted:
1/1/00 12:00am
Subject:
electrician people - here's a question for you.
|
Nice site, apparently it is destined to be discontinued on May 1st. People may want to save info valuable to them.
|
Manesero
Posts: 32
Registered: 2001-12-21 13:39:15
|
Date Posted:
1/1/00 12:00am
Subject:
electrician people - here's a question for you.
|
Problem fixed. Thanks guys
-----signature-----
|
Mangler_SC
Title: Bellybutton Lint Collector
Posts: 1,856
Registered: 2003-12-2 08:37:05
|
Date Posted:
1/1/00 12:00am
Subject:
electrician people - here's a question for you.
|
You used pumpernickel rye instead of regular rye?
-----signature-----
.
Mangler had an accident on the way home from the liquor store. He was run off the road and crashed into a woman's clinic. It was one giant Pabst smear.
-Bou_Te
.
Soylent CLiKK -- It's PEEEEEOPLEEE
|
Tipztoe
Posts: 1,775
Registered: 2004-3-1 17:53:43
|
Date Posted:
1/1/00 12:00am
Subject:
electrician people - here's a question for you.
|
|
my only advice is to spend the money and get LED spotlights.
Not only do they use a fraction of what Halogen does for electricity, they more importantly are "invisible" to bugs.. so you won't have a swarm hovering around them like regular bulbs.
|